This site uses cookies. By continuing to browse the ConceptDraw site you are agreeing to our Use of Site Cookies.
This sample was created on the base of the floor plan with security system device symbols from the website of the California State University, Sacramento. [imet.csus.edu/ imet1/ denyer/ mhs_ denyer/ drafting/ arch_ ch_ 31/ 31-28.jpg]
Legend for the security system hardware includes distribution panel, window-door contact, sonic detector, key pads, heat detectors, smoke detectors.
The example "Security system floor plan" was created using the ConceptDraw PRO diagramming and vector drawing software extended with the Security and Access Plans solution from the Building Plans area of ConceptDraw Solution Park.
Security system floor plan
Security system floor plan, window, casement, window contact sensor, water heater, toilet, smoke detector, sink, security control panel, refrigerator, upright freezer, potted plant, pilaster, pedestal sink, overhead door, keypad device, infrasonic, heat detector, glider window, double bi-fold door, door contact sensor, door, countertop, corner counter, cooker, stretchable, built-in, dishwasher, built-in, bath, bi-fold door, bent counter,
The vector stencils library Alarm and access control contains 80 symbols of digital proximity equipment, locking hardware, and access control equipment.
"An alarm device or system of alarm devices gives an audible, visual or other form of alarm signal about a problem or condition. Alarm devices are often outfitted with a siren." [Alarm device. Wikipedia]
"An access control point, which can be a door, turnstile, parking gate, elevator, or other physical barrier, where granting access can be electronically controlled. Typically, the access point is a door. An electronic access control door can contain several elements. At its most basic, there is a stand-alone electric lock. The lock is unlocked by an operator with a switch. To automate this, operator intervention is replaced by a reader. The reader could be a keypad where a code is entered, it could be a card reader, or it could be a biometric reader. Readers do not usually make an access decision, but send a card number to an access control panel that verifies the number against an access list. To monitor the door position a magnetic door switch can be used. In concept, the door switch is not unlike those on refrigerators or car doors. Generally only entry is controlled, and exit is uncontrolled. In cases where exit is also controlled, a second reader is used on the opposite side of the door. In cases where exit is not controlled, free exit, a device called a request-to-exit (REX) is used. Request-to-exit devices can be a push-button or a motion detector. When the button is pushed, or the motion detector detects motion at the door, the door alarm is temporarily ignored while the door is opened. Exiting a door without having to electrically unlock the door is called mechanical free egress. This is an important safety feature. In cases where the lock must be electrically unlocked on exit, the request-to-exit device also unlocks the door." [Access control. Wikipedia]
Use the design elements library Alarm and access control for drawing layout floor plans, blueprints, and wiring diagrams of intrusion systems, time and attendance systems, card and code access control security systems, internal and external security control systems using the ConceptDraw PRO diagramming and vector drawing software.
The shapes library Alarm and access control is included in the Security and Access Plans solution from the Building Plans area of ConceptDraw Solution Park.
Alarm and access control symbols
Alarm and access control symbols, window contact sensor, weatherproof, horn, siren, wall motion sensor, motion sensor, volumetric capacity detector, vibration sensor, shock sensor, vehicle loop detector, user control keyswitch, user control digital keypad, ultrasonic transceiver, turnstile, transformer, traffic arm, strobe, space detection device, smoke detector, slave tape dialer, slave digital communicator, siren, security window screen, security keypad, security door contact, security control unit, security control panel, security card reader, screen alarm, revolving door, remote zone annunciator, receiver, pushbutton, passive infrared, panic button, overhead door contact sensor, door contact sensor, motion detector, microwave transceiver, master intercom, mains supply power source, magnetic lock, security door alarm, line cut monitor, keypad device, keypad, intercom unit, infrasonic, infrared detector, horn, strobe, horn, siren, heat detector, glass break detector, gas detector, foil on glass detector, foil, floor motion sensor, motion sensor, floor mat, flood sensor, exit device, emergency power, emergency battery, electronic lock, electric door strike, electric door opener, dual technology device, driveway sensor, doorbell, door contact sensor, door chime, door buzzer, dial-up remote equipment, control unit, contact switch surface, contact switch flush, card reader, time, attendance, card reader, keypad, card access reader, card access, carbon monoxide detector, CO detector, camera, keypad, camera, intercom, camera, card reader, camera, biometric access reader, biometric access, beam fence disturbance, PIR field of view,

 physical security plan, security chart, access chart, security plans, access schemes, access plans , CCTV Security and Access Plans

 physical security plan, security chart, access chart, security plans, access schemes, access plans , CCTV
This solution extends ConceptDraw PRO software with physical security plan, security chart, access chart, security plans, access schemes, access plans , CCTV System Plan samples, templates and libraries of design elements for drawing the Security and Acce
The vector stencils library Initiation and annunciation contains 9 symbols of Fire Alarm Control Panel (FACP) or Fire Alarm Control Unit (FACU) elements, triggering devices, audible alarm systems, timers, security control equipment, and recording devices.
"A Fire Alarm Control Panel (FACP), or Fire Alarm Control Unit (FACU), is the controlling component of a Fire Alarm System. The panel receives information from environmental sensors designed to detect changes associated with fire, monitors their operational integrity and provides for automatic control of equipment, and transmission of information necessary to prepare the facility for fire based on a predetermined sequence. The panel may also supply electrical energy to operate any associated sensor, control, transmitter, or relay. There are four basic types of panels: coded panels, conventional panels, addressable panels, and multiplex systems." [Fire alarm control panel. Wikipedia]
Use the shapes library Initiation and annunciation to draw layout floor plans, communications schematics and wiring diagrams of security systems using the ConceptDraw PRO diagramming and vector drawing software.
The design elements library Initiation and annunciation is included in the Security and Access Plans solution from the Building Plans area of ConceptDraw Solution Park.
Initiation and annunciation symbols
Initiation and annunciation symbols, two way radio, printer, multiplex panel, keyboard, intercom, document destroyer, control panel, audio device, CPU, central processing unit,
The vector stencils library Video surveillance contains 15 symbols of electronic closed-circuit television (CCTV) equipment, digital video cameras and recording devices and covert video equipment.
"Closed-circuit television (CCTV) is the use of video cameras to transmit a signal to a specific place, on a limited set of monitors. It differs from broadcast television in that the signal is not openly transmitted, though it may employ point to point (P2P), point to multipoint, or mesh wireless links. Though almost all video cameras fit this definition, the term is most often applied to those used for surveillance in areas that may need monitoring such as banks, casinos, airports, military installations, and convenience stores.
In industrial plants, CCTV equipment may be used to observe parts of a process from a central control room, for example when the environment is not suitable for humans. CCTV systems may operate continuously or only as required to monitor a particular event. A more advanced form of CCTV, utilizing digital video recorders (DVRs), provides recording for possibly many years, with a variety of quality and performance options and extra features (such as motion-detection and email alerts). More recently, decentralized IP cameras, some equipped with megapixel sensors, support recording directly to network-attached storage devices, or internal flash for completely stand-alone operation. Surveillance of the public using CCTV is particularly common in many areas around the world." [Closed-circuit television. Wikipedia]
Use the design elements library Video surveillance to design the layout plans of security and access systems, and internal and external video surveillance and security control monitoring systems using the ConceptDraw PRO diagramming and vector drawing software.
The shapes library Video surveillance is included in the Security and Access Plans solution from the Building Plans area of ConceptDraw Solution Park.
Video surveillance symbols
Video surveillance symbols, video multiplexer, video motion detector, video control keyboard, video keyboard, security window screen, alarm, screening device, recorder, push button, motion detector, monitor, manually operated switch, switch, manual, glass break sensor, camera,  pan, tilt, zoom, camera, bi-static beam sensor, automatic monitoring switch, switch, automatic ,