This site uses cookies. By continuing to browse the ConceptDraw site you are agreeing to our Use of Site Cookies.

Electrical Symbols — Thermo

A thermocouple is an electrical device consisting of two different conductors forming electrical junctions at differing temperatures. A thermocouple produces a temperature-dependent voltage as a result of the thermoelectric effect, and this voltage can be interpreted to measure temperature. Thermocouples are a widely used type of temperature sensor. 26 libraries of the Electrical Engineering Solution of ConceptDraw PRO make your electrical diagramming simple, efficient, and effective. You can simply and quickly drop the ready-to-use objects from libraries into your document to create the electrical diagram.

Electrical Symbols — Resistors

A resistor is a passive two-terminal electrical component that implements electrical resistance as a circuit element. Resistors may be used to reduce current flow, and, at the same time, may act to lower voltage levels within circuits. In electronic circuits, resistors are used to limit current flow, to adjust signal levels, bias active elements, and terminate transmission lines among other uses. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity. 26 libraries of the Electrical Engineering Solution of ConceptDraw PRO make your electrical diagramming simple, efficient, and effective. You can simply and quickly drop the ready-to-use objects from libraries into your document to create the electrical diagram.

Electrical Symbols — Switches and Relays

In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another. The mechanism of a switch may be operated directly by a human operator to control a circuit (for example, a light switch or a keyboard button), may be operated by a moving object such as a door-operated switch, or may be operated by some sensing element for pressure, temperature or flow. A relay is a switch that is operated by electricity. Switches are made to handle a wide range of voltages and currents; very large switches may be used to isolate high-voltage circuits in electrical substations. 26 libraries of the Electrical Engineering Solution of ConceptDraw PRO make your electrical diagramming simple, efficient, and effective. You can simply and quickly drop the ready-to-use objects from libraries into your document to create the electrical diagram.
The vector stencils library "HVAC controls" contains 23 symbols of HVAC controls (sensors, actuators, timers, controllers, I/ O points).
"HVAC (... Heating, Ventilation and Air Conditioning) is a control system that applies regulation to a heating and/ or air conditioning system. ...
Central controllers and most terminal unit controllers are programmable, meaning the direct digital control program code may be customized for the intended use. The program features include time schedules, setpoints, controllers, logic, timers, trend logs, and alarms. The unit controllers typically have analog and digital inputs that allow measurement of the variable (temperature, humidity, or pressure) and analog and digital outputs for control of the transport medium (hot/ cold water and/ or steam). Digital inputs are typically (dry) contacts from a control device, and analog inputs are typically a voltage or current measurement from a variable (temperature, humidity, velocity, or pressure) sensing device. Digital outputs are typically relay contacts used to start and stop equipment, and analog outputs are typically voltage or current signals to control the movement of the medium (air/ water/ steam) control devices such as valves, dampers, and motors." [HVAC control system. Wikipedia]
Use the design elements library "HVAC controls" for drawing the HVAC system diagrams, controls drawings, and automated building control and environmental control system layuout floor plans using the ConceptDraw PRO diagramming and vector drawing software.
The shapes library "HVAC controls" is included in the HVAC Plans solution from the Building Plans area of ConceptDraw Solution Park.
HVAC control symbols
HVAC control symbols, wire note, wiring note, voltage sensor, velocity sensor, water, air, timer, time clock, text label, temperature sensor
, smoke detector, smoke controller
, sensor, pressure sensor, power sensor, power connection, light sensor, input, output, point, humidity sensor
, fluid, level, flow sensor, water, air
, equipment vibration sensor, vibration sensor, equipment rotation sensor, rotation sensor, enthalpy sensor, end switch, limit switch, current sensor, air quality sensor, actuator,

Electrical Symbols — Electrical Circuits

A circuit diagram or wiring diagram uses symbols to represent parts of a circuit. Electrical and electronic circuits can be complicated. Making a drawing of the connections to all the component parts in the circuit's load makes it easier to understand how circuit components are connected. Drawings for electronic circuits are called "circuit diagrams". Drawings for electrical circuits are called "wiring diagrams". 26 libraries of the Electrical Engineering Solution of ConceptDraw PRO make your electrical diagramming simple, efficient, and effective. You can simply and quickly drop the ready-to-use objects from libraries into your document to create the electrical diagram.
The vector stencils library "HVAC controls" contains 23 symbols of HVAC controls (sensors, actuators, timers, controllers, I/ O points). Use it for drawing HVAC system diagrams, controls drawings, and automated building control and environmental control systems design. The example "HVAC controls - Vector stencils library" was created using the ConceptDraw PRO diagramming and vector drawing software extended with the HVAC Plans solution from the Building Plans area of ConceptDraw Solution Park.
Temperature sensor
Temperature sensor, temperature sensor
,
Humidity sensor
Humidity sensor, humidity sensor
,
Enthalpy sensor
Enthalpy sensor, enthalpy sensor,
Pressure sensor
Pressure sensor, pressure sensor,
Flow sensor
Flow sensor, flow sensor, water, air
,
Velocity sensor
Velocity sensor, velocity sensor, water, air,
Voltage sensor
Voltage sensor, voltage sensor,
General purpose sensor
General purpose sensor, sensor,
Light sensor
Light sensor, light sensor,
Rotation sensor
Rotation sensor, equipment rotation sensor, rotation sensor,
Vibration sensor
Vibration sensor, equipment vibration sensor, vibration sensor,
Timer
Timer, timer, time clock,
Current sensor
Current sensor, current sensor,
Power sensor
Power sensor, power sensor,
Air quality sensor
Air quality sensor, air quality sensor,
Level
Level, fluid, level,
End switch
End switch, end switch, limit switch,
Smoke detector
Smoke detector, smoke detector, smoke controller
,
Power connection
Power connection, power connection,
Actuator
Actuator, actuator,
I/O point
I/O point, input, output, point,
Label
Label, text label,
Wire note
Wire note, wire note, wiring note,
The vector stencils library "HVAC controls" contains 23 symbols of HVAC controls (sensors, actuators, timers, controllers, I/ O points).
"HVAC (... Heating, Ventilation and Air Conditioning) is a control system that applies regulation to a heating and/ or air conditioning system. ...
Central controllers and most terminal unit controllers are programmable, meaning the direct digital control program code may be customized for the intended use. The program features include time schedules, setpoints, controllers, logic, timers, trend logs, and alarms. The unit controllers typically have analog and digital inputs that allow measurement of the variable (temperature, humidity, or pressure) and analog and digital outputs for control of the transport medium (hot/ cold water and/ or steam). Digital inputs are typically (dry) contacts from a control device, and analog inputs are typically a voltage or current measurement from a variable (temperature, humidity, velocity, or pressure) sensing device. Digital outputs are typically relay contacts used to start and stop equipment, and analog outputs are typically voltage or current signals to control the movement of the medium (air/ water/ steam) control devices such as valves, dampers, and motors." [HVAC control system. Wikipedia]
Use the design elements library "HVAC controls" for drawing the HVAC system diagrams, controls drawings, and automated building control and environmental control system layuout floor plans using the ConceptDraw PRO diagramming and vector drawing software.
The shapes library "HVAC controls" is included in the HVAC Plans solution from the Building Plans area of ConceptDraw Solution Park.
HVAC control symbols
HVAC control symbols, wire note, wiring note, voltage sensor, velocity sensor, water, air, timer, time clock, text label, temperature sensor
, smoke detector, smoke controller
, sensor, pressure sensor, power sensor, power connection, light sensor, input, output, point, humidity sensor
, fluid, level, flow sensor, water, air
, equipment vibration sensor, vibration sensor, equipment rotation sensor, rotation sensor, enthalpy sensor, end switch, limit switch, current sensor, air quality sensor, actuator,
The vector stencils library "Switches and relays" contains 58 symbols of electrical contacts, switches, relays, circuit breakers, selectors, connectors, disconnect devices, switching circuits, current regulators, and thermostats for electrical devices.
"In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.
The most familiar form of switch is a manually operated electromechanical device with one or more sets of electrical contacts, which are connected to external circuits. Each set of contacts can be in one of two states: either "closed" meaning the contacts are touching and electricity can flow between them, or "open", meaning the contacts are separated and the switch is nonconducting. The mechanism actuating the transition between these two states (open or closed) can be either a "toggle" (flip switch for continuous "on" or "off") or "momentary" (push-for "on" or push-for "off") type.
A switch may be directly manipulated by a human as a control signal to a system, such as a computer keyboard button, or to control power flow in a circuit, such as a light switch. Automatically operated switches can be used to control the motions of machines, for example, to indicate that a garage door has reached its full open position or that a machine tool is in a position to accept another workpiece. Switches may be operated by process variables such as pressure, temperature, flow, current, voltage, and force, acting as sensors in a process and used to automatically control a system. ... A switch that is operated by another electrical circuit is called a relay. Large switches may be remotely operated by a motor drive mechanism. Some switches are used to isolate electric power from a system, providing a visible point of isolation that can be padlocked if necessary to prevent accidental operation of a machine during maintenance, or to prevent electric shock." [Switch. Wikipedia]
"A relay is an electrically operated switch. Many relays use an electromagnet to mechanically operate a switch, but other operating principles are also used, such as solid-state relays. Relays are used where it is necessary to control a circuit by a low-power signal (with complete electrical isolation between control and controlled circuits), or where several circuits must be controlled by one signal. The first relays were used in long distance telegraph circuits as amplifiers: they repeated the signal coming in from one circuit and re-transmitted it on another circuit. Relays were used extensively in telephone exchanges and early computers to perform logical operations.
A type of relay that can handle the high power required to directly control an electric motor or other loads is called a contactor. Solid-state relays control power circuits with no moving parts, instead using a semiconductor device to perform switching. Relays with calibrated operating characteristics and sometimes multiple operating coils are used to protect electrical circuits from overload or faults; in modern electric power systems these functions are performed by digital instruments still called "protective relays"." [Relay. Wikipedia]
The shapes example "Design elements - Switches and relays" was drawn using the ConceptDraw PRO diagramming and vector drawing software extended with the Electrical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Switch and relay symbols
Switch and relay symbols, two way contact, time delay make, open switch, time-delay closing, TDC, time delay make, normally open, time delay break, normally closed, time delay break, closed switch, time-delay opening, TDO, thermostat, temperature switch, temperature sensitive switch, temperature actuated switch, switch disconnector, isolating-switch, stay put, contact without spring return, spring return, make, spring return, break, spring return, shorting selector, make-before-break, shorting, bridging,  contact transfer, selector switch, break-before-make, nonshorting, nonbridging, contact transfer, safety interlock, circuit opening, relay contacts, relay coil, relay, pushbutton, make, circuit closing, mushroom head, push-pull head, pushbutton, break, circuit opening, mushroom head, push-pull head, pushbutton, 2-circuit, circuit opening, break, proximity limit switch, directly actuated, spring returned, normally closed, pressure actuated switch, pilot light, passing make-contact, mercury switch, manual switch, manually operated switch, make contact, liquid level actuated switch, limit switch, directly actuated, spring returned, normally open, limit switch, directly actuated, spring returned, normally closed, limit switch, isolator, inertia switch, gas flow actuated switch, fuse, flow actuated, circuit breaker, change-over contact, break contact, SPST, single-pole, single-throw, switch, SPDT, single-pole, double-throw, switch, DPST, double-pole, single-throw, switch, DPDT, double-pole, double-throw, switch, 4 position, switch, 3 position, three-position, switch, 2 position, switch,
The vector stencils library "Switches" contains 25 symbols of electrical and light switches and breakers.
"In electrical engineering, a switch is an electrical component that can break an electrical circuit, interrupting the current or diverting it from one conductor to another.
The most familiar form of switch is a manually operated electromechanical device with one or more sets of electrical contacts, which are connected to external circuits.
A switch may be directly manipulated by a human as a control signal to a system, ... or to control power flow in a circuit, such as a light switch. Automatically operated switches can be used to control the motions of machines, for example, to indicate that a garage door has reached its full open position or that a machine tool is in a position to accept another workpiece. Switches may be operated by process variables such as pressure, temperature, flow, current, voltage, and force, acting as sensors in a process and used to automatically control a system. For example, a thermostat is a temperature-operated switch used to control a heating process. A switch that is operated by another electrical circuit is called a relay." [Switch. Wikipedia]
Use the design elements library "Switches" for drawing light switches layouts, electrical and telecommunication equipment floor plans for building design and construction using the ConceptDraw PRO diagramming and vector drawing software.
The shapes library "Switches" is included in the Electric and Telecom Plans solution from the Building Plans area of ConceptDraw Solution Park.
Electrical switch symbols
Electrical switch symbols, weatherproof, circuit breaker, weatherproof switch, weatherproof fused switch, three-way switch, switch, timer, switch, pilot lamp, switch control, single pole, double throw switch, single pole switch, remote control switch, momentary contact switch, low voltage, switch, low voltage, master switch, key operated switch, pilot light, key operated switch, horizontally mounted, switch, glow switch toggle, fused switch, four-way switch, electrolier switch, double pole switch, dimmer switch, circuit breaker, automatic door switch,
The vector stencils library "Thermo" contains 14 symbols of thermoelectric elements: thermal element, thermocouples with and without heating elements, thermoplile.
Use it for drawing electrical layouts, electronic schematics, and circuit diagrams.
"The thermoelectric effect is the direct conversion of temperature differences to electric voltage and vice versa. A thermoelectric device creates voltage when there is a different temperature on each side. Conversely, when a voltage is applied to it, it creates a temperature difference. At the atomic scale, an applied temperature gradient causes charge carriers in the material to diffuse from the hot side to the cold side.
This effect can be used to generate electricity, measure temperature or change the temperature of objects. Because the direction of heating and cooling is determined by the polarity of the applied voltage, thermoelectric devices can be used as temperature controllers.
The term "thermoelectric effect" encompasses three separately identified effects: the Seebeck effect, Peltier effect, and Thomson effect. Textbooks may refer to it as the Peltier–Seebeck effect. ...
Thermocouples and thermopiles are devices that use the Seebeck effect to measure the temperature difference between two objects, one connected to a voltmeter and the other to the probe. The temperature of the voltmeter, and hence that of the material being measured by the probe, can be measured separately using cold junction compensation techniques." [Thermoelectric effect. Wikipedia]
The shapes example "Design elements - Thermo" was drawn using the ConceptDraw PRO diagramming and vector drawing software extended with the Electrical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Thermoelectric elements
Thermoelectric elements, thermopile, thermal element, thermomechanical transducer, temperature-measuring, thermocouple, non-insulated heating element, temperature-measuring, thermocouple, insulated heating element, temperature-measuring, thermocouple,
"HVAC (stands for Heating, Ventilation and Air Conditioning) is a control system that applies regulation to a heating and/ or air conditioning system. Usually a sensing device is used to compare the actual state (e.g., temperature) with a target state. Then the control system draws a conclusion what action has to be taken (e.g., start the blower).
More complex HVAC systems can interface to Building Automation System (BAS) to allow the building owners to have more control over the heating or cooling units. The building owner can monitor the system and respond to alarms generated by the system from local or remote locations." [HVAC control system. Wikipedia]
The vector stencils library "HVAC control equipment" contains 48 symbols of heating, ventilation, air conditioning, refrigeration and automated building control equipment.
Use the design elements library HVAC control equipment to draw HVAC plans, schematic diagrams of heating, ventilation, air conditioning, refrigeration and automated building control systems, environmental control design building plans and equipment layouts using the ConceptDraw PRO diagramming and vector drawing software.
The shapes library HVAC control equipment is contained in the HVAC Plans solution from the Building Plans area of ConceptDraw Solution Park.
HVAC control equipment symbols
HVAC control equipment symbols, water flow meter, vane axial fan, pitch control, valve, unit heater, supply duct, return duct, pump, propeller fan, pipe flow arrow, pipe, multi fan section, magnetic, starter, humidifier, heating, cooling, coil, heat exchanger, plate and tube, filter, fan coil housing, equipment, duct extension, duct, damper, cooling tower, converter, chiller, centrifugal fan, boiler
, air flow station, VSD, variable speed drive, VAV box, variable air volume box, DD-VAV box, double, duct, variable air volume box, VAV box, constant volume box, CV box,
The vector stencils library "Valve assembly" contains 141 symbols of pressure and flow regulators, flow direction indicators, controls, and symbols to design flow paths of control valves.
Use these valve assembly shapes to design the engineering drawings of hydraulic and pneumatic valve assemblies in fluid power systems.
"Control valves are valves used to control conditions such as flow, pressure, temperature, and liquid level by fully or partially opening or closing in response to signals received from controllers that compare a "setpoint" to a "process variable" whose value is provided by sensors that monitor changes in such conditions.
The opening or closing of control valves is usually done automatically by electrical, hydraulic or pneumatic actuators. Positioners are used to control the opening or closing of the actuator based on electric, or pneumatic signals.
A control valve consists of three main parts in which each part exist in several types and designs: Valve's actuator, Valve's positioner, Valve's body.
" [Control valves. Wikipedia]
The shapes example "" was created using the ConceptDraw PRO diagramming and vector drawing software extended with the Mechanical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Valve assembly symbols
Valve assembly symbols, variable arrow, valve, two-position, ports, valve, two-position, five ports, valve, three-position, ports, valve, three-position, five ports, valve, four-position, ports, valve, four-position, five ports, two-port, flow path, two-port, closed, flow path, three-port, flow path, three-port, crossover, flow path, spring, variable spring, non-variable spring, shaft, rod, shaft, direction, rotation, rotary connection, line junction, roller, one-way trip, rod, restriction, fluid flow, pull, push, button, pneumatic, fluid flow, plunger, variable plunger, non-variable plunger, pilot-operated, pedal, treadle, over - center, manual override, manual operation, lever, latch, junction, crossing, indication, temperature, temperature control, hydraulic, fluid flow, four-port, tandem, flow path, four-port, semi-connected, flow path, four-port, open, flow path, four-port, flow path, four-port, crossover, flow path, four-port, crossed, flow path, four-port, closed, flow path, fluid energy, pneumatic, hydraulic, energy source, fluid energy, pneumatic, energy source, fluid energy, hydraulic, energy source, flow path, flexible line, five-port, flow path, five-port, crossover, flow path, five-port, closed, flow path, electric, electrical, functional element, electric rotor, electric linear, solenoid, dot, line, junction, detent, curved arrow, direction, rotation, closed path, closed port, box, flow path, arrow, flow path, direction, rectilinear motion, air exhaust port, air bleed, connection,
The vector stencils library "Fluid power valves" contains 93 symbols of pre-made hydraulic and pneumatic valves, including directional control valves, flow control valves, pressure control valves, and electrohydraulic and electropneumatic valves.
"Control valves are valves used to control conditions such as flow, pressure, temperature, and liquid level by fully or partially opening or closing in response to signals received from controllers that compare a "setpoint" to a "process variable" whose value is provided by sensors that monitor changes in such conditions.
The opening or closing of control valves is usually done automatically by electrical, hydraulic or pneumatic actuators. Positioners are used to control the opening or closing of the actuator based on electric, or pneumatic signals.
A control valve consists of three main parts in which each part exist in several types and designs: Valve's actuator, Valve's positioner, Valve's body.
" [Control valves. Wikipedia]
The shapes example "Design elements - Fluid power valves" was created using the ConceptDraw PRO diagramming and vector drawing software extended with the Mechanical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Fluid power valve symbols
Fluid power valve symbols, two-stage, pressure relief, valve, provision, remote control, two-port, two-position, valve, three-port, two-position, valve, restrictor valve, pressure relief, sequence valve, pressure reducing, regulator, valve, one-way restrictor, valve, free flow, one direction, variable restriction, flow, non-return, valve, gate-valve, four-port, two-position, valve, four-port, three-position, valve, flow divider, valve, flow control, valvel, series flow, flow control, valve, temperature compensated, flow control, valve, bypass flow control, five-port, two-position, valve, five-port, three-position, valve, electrically operated, pressure relief, valve, coupling, disconnected, self-sealing, quick release, mechanically operated valves, coupling, disconnected, self-sealing, quick release, coupling, connected, self-sealing, quick release, mechanically operated valves, coupling, connected, self-sealing, quick release, cartridge valve,
The vector stencils library "Lamps, acoustics, readouts" contains 35 element symbols of lamps, acoustic components, electrical measuring instruments for drawing electrical schematics and electronic circuit diagrams.
"Electrical measurements are the methods, devices and calculations used to measure electrical quantities. Measurement of electrical quantities may be done to measure electrical parameters of a system. Using transducers, physical properties such as temperature, pressure, flow, force, and many others can be converted into electrical signals, which can then be conveniently measured and recorded." [Electrical measurements. Wikipedia]
"A lamp is a replaceable component such as an incandescent light bulb, which is designed to produce light from electricity." [Lamp (electrical component). Wikipedia]
"An electric bell is a mechanical bell that... functions by means of an electromagnet. When an electric current is applied, it produces a repetitive buzzing or clanging sound." [Electric bell. Wikipedia]
"A buzzer or beeper is an audio signalling device, which may be mechanical, electromechanical, or piezoelectric." [Buzzer. Wikipedia]
"Electronic sirens incorporate circuits such as oscillators, modulators, and amplifiers to synthesize a selected siren tone (wail, yelp, pierce/ priority/ phaser, hi-lo, scan, airhorn, manual, and a few more) which is played through external speakers." [Siren (noisemaker). Wikipedia]
"A microphone (colloquially called a mic or mike...) is an acoustic-to-electric transducer or sensor that converts sound in air into an electrical signal. ...
Most microphones today use electromagnetic induction (dynamic microphone), capacitance change (condenser microphone) or piezoelectric generation to produce an electrical signal from air pressure variations." [Microphone. Wikipedia]
The symbols example "Design elements - Lamps, acoustics, readouts" was drawn using the ConceptDraw PRO diagramming and vector drawing software extended with the Electrical Engineering solution from the Engineering area of ConceptDraw Solution Park.
Lamps, acoustics, electrical measuring instruments
Lamps, acoustics, electrical measuring instruments, speaker, microphone, speaker, microphone, push-pull, microphone, capacitor, microphone, lamp, signal lamp, lamp, non-indicating lamp, lamp, indicating lamp, lamp, indicator, meter, wavemeter, indicator, meter, voltmeter, indicator, meter, thermometer, indicator, meter, synchroscope, indicator, meter, oscilloscope, indicator, meter, galvanometer, indicator, meter, frequency meter, indicator, meter, ammeter, fluorescent lamp, buzzer, bell, siren, bell,
The vector stencils library "Fluid power equipment" contains 113 symbols of hydraulic and pneumatic equipment including pumps, motors, air compressors, cylinders, meters, gauges, and actuators.
Use it to design fluid power and hydraulic control systems in the ConceptDraw PRO diagramming and vector drawing software extended with the Mechanical Engineering solution from the Engineering area of ConceptDraw Solution Park.
www.conceptdraw.com/ solution-park/ engineering-mechanical
Actuator (semi-rotary), pneumatic
Actuator (semi-rotary), pneumatic, semi-rotary, actuator, limited angle, rotation,
Actuator (semi-rotary), hydraulic
Actuator (semi-rotary), hydraulic, semi-rotary, actuator, limited angle, rotation,
Drive unit, pneumatic
Drive unit, pneumatic, pneumatic, drive unit, variable speed,
Drive unit, hydraulic
Drive unit, hydraulic, hydraulic, drive unit, variable speed,
Sgl-act. cylinder, pneum., left spring
Sgl-act. cylinder, pneum., left spring, single-acting, pneumatic, cylinder,
Sgl-act. cylinder, pneum., right spring
Sgl-act. cylinder, pneum., right spring, single-acting, pneumatic, cylinder,
Sgl-act. cylinder, pneumatic
Sgl-act. cylinder, pneumatic, single-acting, pneumatic, cylinder,
Sgl-act. cylinder, hydr., left spring
Sgl-act. cylinder, hydr., left spring, single-acting, hydraulic, cylinder,
Sgl-act. cylinder, hydr., right spring
Sgl-act. cylinder, hydr., right spring, single-acting, hydraulic, cylinder,
Sgl-act. cylinder, hydraulic
Sgl-act. cylinder, hydraulic, single-acting, hydraulic, cylinder,
Dbl-act. cylinder, pneumatic
Dbl-act. cylinder, pneumatic, double-acting, pneumatic, cylinder,
Dbl-act. cylinder, pneum., sgl cushion
Dbl-act. cylinder, pneum., sgl cushion, double-acting, pneumatic, cylinder,
Dbl-act. cylinder, pneum., dbl cushion
Dbl-act. cylinder, pneum., dbl cushion, double-acting, pneumatic, cylinder,
Dbl-act. cylinder, pneum., adjustable
Dbl-act. cylinder, pneum., adjustable, double-acting, pneumatic, cylinder, adjustable,
Dbl-act. cylinder, pneum., sgl cushion, adj.
Dbl-act. cylinder, pneum., sgl cushion, adj., double-acting, pneumatic, cylinder, adjustable,
Dbl-act. cylinder, pneum., dbl cushion, adj.
Dbl-act. cylinder, pneum., dbl cushion, adj., double-acting, pneumatic, cylinder, adjustable,
Dbl-act. cylinder, hydraulic
Dbl-act. cylinder, hydraulic, double-acting, hydraulic, cylinder,
Dbl-act. cylinder, hydr., sgl cushion
Dbl-act. cylinder, hydr., sgl cushion, double-acting, hydraulic, cylinder,
Dbl-act. cylinder, hydr., dbl cushion
Dbl-act. cylinder, hydr., dbl cushion, double-acting, hydraulic, cylinder,
Dbl-act. cylinder, hydr., adjustable
Dbl-act. cylinder, hydr., adjustable, double-acting, hydraulic, cylinder, adjustable,
Dbl-act. cylinder, hydr., sgl cushion, adj.
Dbl-act. cylinder, hydr., sgl cushion, adj., double-acting, hydraulic, cylinder, adjustable,
Dbl-act. cylinder, hydr., dbl cushion, adj.
Dbl-act. cylinder, hydr., dbl cushion, adj., double-acting, hydraulic, cylinder, adjustable,
Dbl-act. cylinder, magnetic
Dbl-act. cylinder, magnetic, double-acting, magnetic cylinder,
Dbl-act. cylinder, magn., sgl cushion
Dbl-act. cylinder, magn., sgl cushion, double-acting, magnetic cylinder,
Dbl-act. cylinder, magn., dbl cushion
Dbl-act. cylinder, magn., dbl cushion, double-acting, magnetic cylinder,
Dbl-act. cylinder, magn., adjustable
Dbl-act. cylinder, magn., adjustable, double-acting, magnetic cylinder, adjustable,
Dbl-act. cylinder, magn., sgl cushion, adj.
Dbl-act. cylinder, magn., sgl cushion, adj., double-acting, magnetic cylinder, adjustable,
Dbl-act. cylinder, magn., dbl cushion, adj.
Dbl-act. cylinder, magn., dbl cushion, adj., double-acting, magnetic cylinder, adjustable,
Dbl-act. dbl-end. cylinder, pneumatic
Dbl-act. dbl-end. cylinder, pneumatic, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, pneum., sgl cushion
Dbl-act. dbl-end. cylinder, pneum., sgl cushion, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, pneum., dbl cushion
Dbl-act. dbl-end. cylinder, pneum., dbl cushion, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, pneum., adjustable
Dbl-act. dbl-end. cylinder, pneum., adjustable, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, pneum., sgl cushion, adj.
Dbl-act. dbl-end. cylinder, pneum., sgl cushion, adj., double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, pneum., dbl cushion, adj.
Dbl-act. dbl-end. cylinder, pneum., dbl cushion, adj., double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, hydraulic
Dbl-act. dbl-end. cylinder, hydraulic, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, hydr., sgl cushion
Dbl-act. dbl-end. cylinder,  hydr., sgl cushion, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, hydr., dbl cushion
Dbl-act. dbl-end. cylinder,  hydr., dbl cushion, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, hydr., adjustable
Dbl-act. dbl-end. cylinder,  hydr., adjustable, double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, hydr., sgl cushion, adj.
Dbl-act. dbl-end. cylinder,  hydr., sgl cushion, adj., double-acting, double-ended, cylinder,
Dbl-act. dbl-end. cylinder, hydr., dbl cushion, adj.
Dbl-act. dbl-end. cylinder,  hydr., dbl cushion, adj., double-acting, double-ended, cylinder,
Telescopic cylinder, pneum., dbl-act.
Telescopic cylinder, pneum., dbl-act., telescopic, pneumatic, cylinder, double-acting,
Telescopic cylinder, hydr., dbl-act.
Telescopic cylinder, hydr., dbl-act., telescopic, hydraulic, cylinder, double-acting,
Telescopic cylinder, pneum., sgl-act.
Telescopic cylinder, pneum., sgl-act., telescopic, pneumatic, cylinder, single-acting,
Telescopic cylinder, hydr., sgl-act.
Telescopic cylinder, hydr., sgl-act., telescopic, hydraulic, cylinder, single-acting,
Actuator, hydraulic-pneumatic
Actuator, hydraulic-pneumatic, single-acting actuator, converting, pneumatic pressure, hydraulic pressure,
Actuator, pneumatic-hydraulic
Actuator, pneumatic-hydraulic, single-acting actuator, converting, pneumatic pressure, hydraulic pressure,
Intensifier, pneumatic
Intensifier, pneumatic, single-acting, intensifier, converting, pneumatic pressure,
Intensifier, hydraulic
Intensifier, hydraulic, single-acting, intensifier, converting, hydraulic pressure,
Intensifier, hydraulic-pneumatic
Intensifier, hydraulic-pneumatic, single-acting, intensifier, converting, pneumatic pressure, hydraulic pressure,
Intensifier, pneumatic-hydraulic
Intensifier, pneumatic-hydraulic, single-acting, intensifier, converting, pneumatic pressure, hydraulic pressure,
Intensifier, pneumatic-hydraulic
Intensifier, pneumatic-hydraulic, continuous, intensifier, converting, pneumatic pressure, hydraulic pressure,
Intensifier, hydraulic-pneumatic
Intensifier, hydraulic-pneumatic, continuous, intensifier, converting, pneumatic pressure, hydraulic pressure,
Actuator, pneumatic-hydraulic
Actuator, pneumatic-hydraulic, continuous, actuator, converting, pneumatic pressure, hydraulic pressure,
Actuator, hydraulic-pneumatic
Actuator, hydraulic-pneumatic, continuous, actuator, converting, pneumatic pressure, hydraulic pressure,
Accumulator
Accumulator, energy storage device, accumulator,
Accumulator, gas loaded
Accumulator, gas loaded, energy storage device, accumulator, gas loaded accumulator,
Accumulator, spring loaded
Accumulator, spring loaded, energy storage device, accumulator, spring loaded accumulator,
Accumulator, auxiliary gas bottle
Accumulator, auxiliary gas bottle, energy storage device, accumulator, auxiliary gas bottle,
Air receiver
Air receiver, air receiver,
Energy source, pneumatic
Energy source, pneumatic, pneumatic, energy source,
Energy source, hydraulic
Energy source, hydraulic, hydraulic, energy source,
Energy source, electric motor
Energy source, electric motor, energy source, electric motor,
Energy source, non-electric prime mover
Energy source, non-electric prime mover, energy source, non-electric prime mover,
Vented reservoir
Vented reservoir, vented reservoir,
Sealed reservoir
Sealed reservoir, pressurized, sealed, hydraulic, reservoir,
Filter
Filter, filter,
Filter, magnetic element
Filter, magnetic element, filter, magnetic element,
Filter, contamination indicator
Filter, contamination indicator, filter, contamination indicator,
Automatic drain filter separator
Automatic drain filter separator, automatically, drained, separator, valve, filter,
Manual drain filter separator
Manual drain filter separator, manually, drained, separator, valve, filter,
Separator, automatic drain
Separator, automatic drain, automatically, drained, separator, valve,
Separator, manual drain
Separator, manual drain, manually, drained, separator, valve,
Air dryer
Air dryer, air dryer, air drying,
Lubricator
Lubricator, lubricator, oil, air, lubricate,
Air service unit, filter, separator
Air service unit, filter, separator, air service unit, filter, separator,
Air service unit, separator
Air service unit, separator, air service unit, separator,
Air service unit, filter
Air service unit, filter, air service unit, filter,
Air service unit
Air service unit, air service unit,
Liquid cooler
Liquid cooler, heat exchanger, apparatus, cooling, circulating fluid,
Gas cooler
Gas cooler, heat exchanger, apparatus, cooling, circulating fluid,
Cooler
Cooler, heat exchanger, apparatus, cooling, circulating fluid,
Liquid heater
Liquid heater, heat exchanger, apparatus, heating, circulating fluid,
Gas heater
Gas heater, heat exchanger, apparatus, heating, circulating fluid,
Heater
Heater, heat exchanger, apparatus, heating, circulating fluid,
Liquid temperature controller
Liquid temperature controller, liquid temperature controller,
Gas temperature controller
Gas temperature controller, gas temperature controller,
Temperature controller
Temperature controller, temperature controller,
Liquid temperature controller 2
Liquid temperature controller 2, temperature controller, liquid,
Gas temperature controller 2
Gas temperature controller 2, temperature controller, gas,
Temperature controller 2
Temperature controller 2, temperature controller,
Pressure indicator
Pressure indicator, pressure indicator, pressure, indicator,
Pressure gauge
Pressure gauge, pressure gauge, pressure, gauge,
Differential pressure gauge
Differential pressure gauge, differential pressure gauge, pressure, gauge, differential gauge,
Thermometer
Thermometer, thermometer,
Liquid level measuring instrument
Liquid level measuring instrument, liquid level, measuring instrument,
Flow indicator
Flow indicator, flow, measurement, indicator,
Flow meter
Flow meter, flow meter,
Integrating flow meter
Integrating flow meter, flow meter, integrating,
Tachometer
Tachometer, tachometer,
Torque measurement equipment
Torque measurement equipment, torque measurement,
Pressure switch
Pressure switch, switch, pressure switch,
Limit switch
Limit switch, switch, limit switch,
Transducer
Transducer, transducer, analog transducer,
Pulse counter
Pulse counter, pulse counter, electric output signal,
Pulse counter 2
Pulse counter 2, pulse counter, pneumatic output signal,
Silencer
Silencer, silencer, pneumatic silencer,
Drain (inlet below fluid, drain line)
Drain (inlet below fluid, drain line), reservoir,
Drain (inlet below fluid, return line)
Drain (inlet below fluid, return line), reservoir,
Drain (inlet above fluid, drain line)
Drain (inlet above fluid, drain line), reservoir,
Drain (inlet above fluid, return line)
Drain (inlet above fluid, return line), reservoir,
Oil tank
Oil tank, oil tank,
Oil tank, empty
Oil tank, empty, oil tank,
Air compressor
Air compressor, air compressor,